References

Benefits

Medical Aspects

1. “… CROS hearing aids offer a nonsurgical option to compensate for some of the deficits that occur when a listener is limited to a single ear.” (Snapp 2019)

 

2. “The CROS system transmit sound signals from the impaired ear via a wire (or wireless) to a microphone in the better ear.

Compared to Cl, it is relatively inexpensive and non-invasive (…)” (Cho et al. 2020)

 

3. To benefit from CROS hearing aids, no surgery is necessary and therefor in all situations the skin stays intact. (HEARRING consensus)

 

 

More: Bishop et al. 201

1. “As CROS hearing aids are a non-invasive solution, patients can easily try the device according to their needs. (HEARRING consensus)

1. As CROS hearing aids are a non-invasive solution, only the removal of the device is necessary to undergo MRI. (HEARRING consensus)

Patient-reported Aspects

1. ” (…) noninvasive CROS solutions can successfully rehabilitate certain monaural listening deficits, provide improved hearing outcomes, and expand the reach of treatment in this population.” (Snapp et al. 2017)

More: Peters et al. 2015

Drawbacks

Audiological Aspects

1. “(…) rerouting of signal does not result in restoration of binaural function, but serves to reduce the head-shadow effect.” (Snapp et al. 2017)

2. “The biggest limitation of CROS and BiCROS solutions is that binaural hearing is not restored. […] These devices cannot resolve an individual’s impairment for complex auditory tasks heavily reliant on binaural cues provided through binaural hearing, such as binaural summation, binaural squelch, or localization of sounds” (Snapp et al., 2019)

3. “The CROS and bone-anchored hearing aid treatment […] do not allow for real binaural hearing because the brain only receives and processes auditory input from one side.” (Arndt et al. 2011)

More: Bishop et al. 2010Arndt et al. 2017Peters et al. 2015

1. “Bone-anchored hearing aid (BAHA) or contralateral routing of signal (CROS) can improve the head shadow effect but do usually not reduce the perception of tinnitus. ” (Peter et al.2019)

2. “However, for people with severe to profound sensorineural hearing loss, hearing aids and other forms of sound enrichment are not useful for tinnitus treatment. In recent years, patients with severe to profound hearing loss have sought cochlear implantation as a means of tinnitus relief when other treatments were found to be ineffective.” (Holder et al. 2017)

1. “There was no improvement in localization ability in the aided condition and no significant difference in performance with

CROS versus bone-anchored implants (BAI). ” (Snapp et al.2017)

2. “CROS solutions do not provide restoration of binaural hearing and cannot improve tasks requiring binaural input, such as localization.” (Snapp 2019)

More: Arndt et al. 20112017Cho et al. 2020Augustine et al. 2012Niparko et al. 2003Hol et al. 20042009Peters et al. 2015

1. “[Speech reception thresholds) were also impaired significantly by both [air conduction and bone conduction rerouting] device types when noise was presented toward the impaired ear. ” (Kitterick et al. 2016)

More: Arndt et al. 2011, 2017Finbow et al. 2015Snapp et al.2017

Patient-reported Aspects

1. “Most patients found it unpleasant to have an earmold with partial occlusion in their hearing ear (…)” (Müller-Isberner et al. 2015)

More: Lin et al. 2006Lindsey 2009Ryu et al. 2014